Tender For supply of safety jacket , safety belt , cotton hand gloves , electrical hand gloves , lagther hand gloves , retro reflective board , aspirator , air sampling bag with si pipe
Tender For supply, installation, testing and commissioning of cavitatory ultrasonic suction and aspirator - cusa (1nos) for surgical gastroenterology dept. of kem hospital along with standard accessories and cmc for seven years after the completion of warranty of three years mahatender id.2026_mcgm_ 1279634_1.
Tender For supply, installation, testing and commissioning of cavitatory ultrasonic suction and aspirator - cusa for surgical gastroenterology dept. of kem hospital along with standard accessories and cmc for seven years after the completion of warranty of three years
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For corrigendum : sch 11 rubber goods by tender - sch xi (supply of rubber goods), triple, sterile, pyrogen free, transperent, leak proof pvc bags. primary bag having 350ml capacity and tow satelliet bag of 300ml capacity. dual packaging (individual & aluminium) eliminating microbial contamination on surface maintaining the contents of the bag. ultra thin walled 16g venipuncture needle as specified in iso 1135-3. high flexible & kink resistant bloodcollectingtube includes serial number for precise easy identification.easy to break off valve. safe & easy to open outlet port. rounded corners. highly transparent virgin grade pvc material/providing platlet 5 days storage bags. high quality peel resistant label. cpda anticoagulant (usp). should with stand temperature - 70 to + 37 c. labels must have mfg. date, expiry date. batch no. manufacturer must give test reports as per ip/bp/usp standards., triple, sterile, pyrogen free, transperent, leak proof pvc bags. primary bag having 350ml capacity and two satelliet bag of 300 ml capacity. sagm - 75- 80ml. cpd/sag- anticoagulant (usp). dual packaging (individual & aluminium) eliminating microbial contamination on surface maintaining the contents of the bag. ultra thin walled 16g venipuncture needle as specified in iso 1135-3. soft twist off needle cover high flexible & kink resistant bloodcollectingtube includes serial number for precise easy identification. easy to break off valve. rounded corners. safe & easy to open outlet port. highly transparent virgin grade pvc material /providing platlet 5 days storage bags. high quality peel resistant label. cpda anticoagulant (usp). labels must have manufacturing date,expiry date, batch no. should withstand temperature -70 to + 37 c. manufacturer must give test reports as per ip/bp/usp standards., catheter no. 3 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no. 4 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no. 5 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no. 6 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no.7 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no. 8 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no.9 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no. 10 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no.11. length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., catheter no.12 length 16". non-irritant red rubber. proximal funnel end and distal rounded atraumatic tip with side-hole., infant feeding tube p.v.c. non-toxic sterile disposable pyrogen free x-ray opaque line & siliconised nos.5 at least two holes. maximum distance of 1 cms between the first hole & the tip of the catheter,with or without graduation marking after every 1 cm.packing should be straight. size - 5, infant feeding tube p.v.c. non-toxic sterile disposable pyrogen free x-ray opaque line & siliconised nos.6 at least two holes. maximum distance of 1 cms between the first hole & the tip of the catheter,with or without graduation marking after every 1 cm.packing should be straight. size - 6, infant feeding tube p.v.c. non-toxic sterile disposable pyrogen free x-ray opaque line & siliconised nos.7 at least two holes. maximum distance of 1 cms between the first hole & the tip of the catheter,with or without graduation marking after every 1 cm.packing should be straight. size - 7, infant feeding tube p.v.c. non-toxi